| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The server identity check mechanism for firmware upgrade performed via command shell is insecurely implemented potentially allowing an attacker to perform a Man-in-the-middle attack. This security issue has been fixed in the latest firmware version of Eaton
Network M3
which is available on the Eaton download center. |
| Eaton Intelligent Power Protector (IPP) is affected by insecure library loading in its executable, which could lead to arbitrary code execution by an attacker with access to the software package. This security issue has been fixed in the latest version of Eaton IPP software which is available on the Eaton download center. |
| A security misconfiguration was identified in Eaton Intelligent Power Protector (IPP), where an HTTP response header was set with an insecure attribute, potentially exposing users to web‑based attacks. This security issue has been fixed in the latest version of Eaton IPP software which is available on the Eaton download centre. |
| Due to improper
input validation in one of the Eaton Intelligent Power Protector (IPP) XML, it is
possible for an attacker with admin privileges and access to the local system to
inject malicious code resulting in arbitrary command execution. This security issue has been fixed in the latest version of Eaton IPP software which is available on the Eaton download centre. |
| Eaton Intelligent Power Protector (IPP) uses an insecure cookie configuration, which could allow a network‑based attacker to intercept the cookie and exploit it through a man‑in‑the‑middle attack. This security issue has been fixed in the latest version of Eaton IPP software which is available on the Eaton download centre. |
| Eaton Intelligent Power Protector (IPP) software allows repeated authentication attempts against the web interface login page due to insufficient rate‑limiting controls. This security issue has been fixed in the latest version of Eaton IPP which is available on the Eaton download centre. |
| The encryption mechanism used in Eaton's EasySoft project file was insecure and susceptible to brute force attacks, an attacker with access to this file and the local host
machine could potentially read the sensitive information stored and tamper with the project file. This security issue has been fixed in the latest version of Eaton EasySoft which is available on the Eaton download centre. |
| The server identity check mechanism for firmware upgrade performed via command shell is insecurely implemented potentially allowing an attacker to perform a Man-in-the-middle attack. This security issue has been fixed in the latest firmware version of Eaton G4 PDU which is available on the Eaton download center. |
| IPP software prior to v1.71 is vulnerable to default credential vulnerability. This could
lead attackers to identify and access vulnerable systems. |
| Improper authentication of library files in the Eaton IPP software installer could lead to arbitrary code execution of an attacker with the access to the software package.
This security issue has been fixed in the latest version of IPP which is available on the Eaton download center. |
| Arbitrary code execution is possible due to improper validation of the file upload functionality in Eaton BLSS. This security issue has been fixed in the latest script patch latest version of of Eaton BLSS (7.3.0.SCP004). |
| The privileged user could log in without sufficient credentials after enabling an application protocol. This security issue has been fixed in the latest script patch latest version of of Eaton BLSS (7.3.0.SCP004). |
| An attacker with authenticated and privileged access could modify the contents of a non-sensitive file by traversing the path in the limited shell of the CLI. This security issue has been fixed in the latest version which is available on the Eaton download center. |
| IPP software versions prior to v1.71 do not sufficiently verify the authenticity of data, in a
way that causes it to accept invalid data. |
| Improper input sanitization in the file archives upload functionality of Eaton Galileo software allows traversing paths which could lead into an attacker with local access to execute unauthorized code or commands. This security issue has been fixed in the latest version of Galileo which is available on the Eaton download center. |
| Improper quotation in search paths in the Eaton UPS Companion software installer could lead to arbitrary code execution of an attacker with the access to the
file system. This security issue has been fixed in the latest version of EUC which is available on the Eaton download center. |
| Improper input validation at one of the endpoints of Eaton xComfort ECI's
web interface, could lead into an attacker with network access to the device executing privileged user commands. As cybersecurity
standards continue to evolve and to meet our requirements today, Eaton has decided to discontinue the
product. Upon retirement or end of support, there will be no new security updates, non-security
updates, or paid assisted support options, or online technical content updates. |
| Due to insecure library loading in the Eaton UPS Companion software executable, an attacker with access to the software package
could perform arbitrary code execution . This security issue has been fixed in the latest version of EUC which is available on the Eaton download center. |
| Improper authentication of library files in the Eaton UPS Companion software installer could lead to arbitrary code execution of an attacker with the access to the software package. This security issue has been fixed in the latest version of EUC which is available on the Eaton download center. |
| Eaton Cooper Power Systems ProView 4.0 and 5.0 before 5.0 11 on Form 6 controls and Idea and IdeaPLUS relays generates TCP initial sequence number (ISN) values linearly, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value. |