Search Results (582 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-7884 1 Eluktronics 1 Control Center 2025-09-15 3.3 Low
A vulnerability classified as problematic was found in Eluktronics Control Center 5.23.51.41. Affected by this vulnerability is an unknown functionality of the component REG File Handler. The manipulation leads to insufficient verification of data authenticity. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-8978 2 D-link, Dlink 3 Dir-619l, Dir-619l, Dir-619l Firmware 2025-09-12 6.6 Medium
A vulnerability was determined in D-Link DIR-619L 6.02CN02. Affected is the function FirmwareUpgrade of the component boa. The manipulation leads to insufficient verification of data authenticity. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2024-28251 1 Pinterest 1 Querybook 2025-09-04 5.6 Medium
Querybook is a Big Data Querying UI, combining collocated table metadata and a simple notebook interface. Querybook's datadocs functionality works by using a Websocket Server. The client talks to this WSS whenever updating/deleting/reading any cells as well as for watching the live status of query executions. Currently the CORS setting allows all origins, which could result in cross-site websocket hijacking and allow attackers to read/edit/remove datadocs of the user. This issue has been addressed in version 3.32.0. Users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2025-54792 1 Localsend 1 Localsend 2025-09-03 6.8 Medium
LocalSend is an open-source app to securely share files and messages with nearby devices over local networks without needing an internet connection. In versions 1.16.1 and below, a critical Man-in-the-Middle (MitM) vulnerability in the software's discovery protocol allows an unauthenticated attacker on the same local network to impersonate legitimate devices, silently intercepting, reading, and modifying any file transfer. This can be used to steal sensitive data or inject malware, like ransomware, into files shared between trusted users. The attack is hardly detectable and easy to implement, posing a severe and immediate security risk. This issue was fixed in version 1.17.0.
CVE-2025-0092 1 Google 1 Android 2025-09-02 6.5 Medium
In handleBondStateChanged of AdapterService.java, there is a possible permission bypass due to misleading or insufficient UI. This could lead to remote (proximal/adjacent) information disclosure with no additional execution privileges needed. User interaction is needed for exploitation.
CVE-2025-0149 1 Zoom 6 Meeting Software Development Kit, Rooms, Rooms Controller and 3 more 2025-08-19 6.5 Medium
Insufficient verification of data authenticity in some Zoom Workplace Apps may allow an unprivileged user to conduct a denial of service via network access.
CVE-2025-8980 1 Tenda 2 G1, G1 Firmware 2025-08-18 6.6 Medium
A vulnerability has been found in Tenda G1 16.01.7.8(3660). Affected by this issue is the function check_upload_file of the component Firmware Update Handler. The manipulation leads to insufficient verification of data authenticity. The attack may be launched remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used.
CVE-2025-8979 1 Tenda 2 Ac15, Ac15 Firmware 2025-08-18 6.6 Medium
A vulnerability was identified in Tenda AC15 15.13.07.13. Affected by this vulnerability is the function check_fw_type/split_fireware/check_fw of the component Firmware Update Handler. The manipulation leads to insufficient verification of data authenticity. The attack can be launched remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.
CVE-2014-9194 1 Arbiter 1 1094b Gps Substation Clock 2025-07-29 N/A
Arbiter 1094B GPS Substation Clock allows remote attackers to cause a denial of service (disruption) via crafted radio transmissions that spoof GPS satellite broadcasts.
CVE-2025-7096 1 Comodo 1 Internet Security 2025-07-18 8.1 High
A vulnerability classified as critical was found in Comodo Internet Security Premium 12.3.4.8162. This vulnerability affects unknown code of the file cis_update_x64.xml of the component Manifest File Handler. The manipulation leads to improper validation of integrity check value. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-37968 1 Microsoft 6 Windows Server 2008, Windows Server 2012, Windows Server 2016 and 3 more 2025-07-10 7.5 High
Windows DNS Spoofing Vulnerability
CVE-2024-38198 1 Microsoft 15 Windows 10 1507, Windows 10 1607, Windows 10 1809 and 12 more 2025-07-10 7.5 High
Windows Print Spooler Elevation of Privilege Vulnerability
CVE-2025-5832 1 Pioneer 2 Dmh-wt7600nex, Dmh-wt7600nex Firmware 2025-07-08 N/A
Pioneer DMH-WT7600NEX Software Update Signing Insufficient Verification of Data Authenticity Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Pioneer DMH-WT7600NEX devices. Authentication is not required to exploit this vulnerability. The specific flaw exists within the software update verification process. The issue results from the lack of validating all the data in the software update. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26079.
CVE-2025-5833 1 Pioneer 2 Dmh-wt7600nex, Dmh-wt7600nex Firmware 2025-07-08 6.8 Medium
Pioneer DMH-WT7600NEX Root Filesystem Insufficient Verification of Data Authenticity Vulnerability. This vulnerability allows physically present attackers to bypass authentication on affected installations of Pioneer DMH-WT7600NEX devices. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the operating system. The issue results from the lack of properly configured protection for the root file system. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-26077.
CVE-2025-48865 1 Fabiolb 1 Fabio 2025-06-04 9.1 Critical
Fabio is an HTTP(S) and TCP router for deploying applications managed by consul. Prior to version 1.6.6, Fabio allows clients to remove X-Forwarded headers (except X-Forwarded-For) due to a vulnerability in how it processes hop-by-hop headers. Fabio adds HTTP headers like X-Forwarded-Host and X-Forwarded-Port when routing requests to backend applications. Since the receiving application should trust these headers, allowing HTTP clients to remove or modify them creates potential security vulnerabilities. Some of these custom headers can be removed and, in certain cases, manipulated. The attack relies on the behavior that headers can be defined as hop-by-hop via the HTTP Connection header. This issue has been patched in version 1.6.6.
CVE-2023-52109 1 Huawei 2 Emui, Harmonyos 2025-06-02 7.5 High
Vulnerability of trust relationships being inaccurate in distributed scenarios. Successful exploitation of this vulnerability may affect service confidentiality.
CVE-2021-4226 1 Rsjoomla 1 Rsfirewall\! 2025-05-27 9.8 Critical
RSFirewall tries to identify the original IP address by looking at different HTTP headers. A bypass is possible due to the way it is implemented.
CVE-2023-32212 2 Mozilla, Redhat 8 Firefox, Firefox Esr, Thunderbird and 5 more 2025-05-27 4.3 Medium
An attacker could have positioned a `datalist` element to obscure the address bar. This vulnerability affects Firefox < 113, Firefox ESR < 102.11, and Thunderbird < 102.11.
CVE-2018-10626 1 Medtronic 4 Mycarelink 24950 Patient Monitor, Mycarelink 24950 Patient Monitor Firmware, Mycarelink 24952 Patient Monitor and 1 more 2025-05-22 4.4 Medium
Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.
CVE-2024-24557 2 Mobyproject, Redhat 2 Moby, Ceph Storage 2025-05-15 6.9 Medium
Moby is an open-source project created by Docker to enable software containerization. The classic builder cache system is prone to cache poisoning if the image is built FROM scratch. Also, changes to some instructions (most important being HEALTHCHECK and ONBUILD) would not cause a cache miss. An attacker with the knowledge of the Dockerfile someone is using could poison their cache by making them pull a specially crafted image that would be considered as a valid cache candidate for some build steps. 23.0+ users are only affected if they explicitly opted out of Buildkit (DOCKER_BUILDKIT=0 environment variable) or are using the /build API endpoint. All users on versions older than 23.0 could be impacted. Image build API endpoint (/build) and ImageBuild function from github.com/docker/docker/client is also affected as it the uses classic builder by default. Patches are included in 24.0.9 and 25.0.2 releases.