| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Ubiquiti U6-LR 6.6.65 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. NOTE: In Ubiquiti's view there is no vulnerability as the Hardcoded Password should be after setup not before. |
| Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000 firmware (used by many white-labeled DVR/NVR/IPC products) contains hardcoded API credentials and an OS command injection flaw in its configuration services. The web/API interface accepts HTTP/XML requests authenticated with a fixed vendor credential string and passes user-controlled fields into shell execution contexts without proper argument sanitization. An unauthenticated remote attacker can leverage the hard-coded credential to access endpoints such as /editBlackAndWhiteList and inject shell metacharacters inside XML parameters, resulting in arbitrary command execution as root. The same vulnerable backend is also reachable in some models through a proprietary TCP service on port 4567 that accepts a magic GUID preface and base64-encoded XML, enabling the same command injection sink. Firmware releases from mid-February 2018 and later are reported to have addressed this issue. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-28 UTC. |
| INIM Electronics Smartliving SmartLAN/G/SI <=6.x contains hard-coded credentials in its Linux distribution image that cannot be changed through normal device operations. Attackers can exploit these persistent credentials to log in and gain unauthorized system access across multiple SmartLiving device models. |
| The default password for the extended admin user mode in the application U9ExosAdmin.exe ("Kaba 9300 Administration") is hard-coded in multiple locations as well as documented in the locally stored user documentation. |
| Use of Hard-coded Credentials vulnerability in Baicells Snap Router BaiCE_BMI on EP3011 (User Passwords modules) allows unauthorized access to the device. |
| Weak account password in GE HealthCare EchoPAC products |
| Multiple hardcoded credentials have been identified, which are allowed to sign-in to the exos 9300 datapoint server running on port 1004 and 1005. This server is used for relaying status information from and to the Access Managers. This information, among other things, is used to graphically visualize open doors and alerts. However, controlling the Access Managers via this interface is also possible.
To send and receive status information, authentication is necessary. The Kaba exos 9300 application contains hard-coded credentials for four different users, which are allowed to login to the datapoint server and receive as well as send information, including commands to open arbitrary doors. |
| The Premium Age Verification / Restriction for WordPress plugin for WordPress is vulnerable to arbitrary file read and write due to the existence of an insufficiently protected remote support functionality in remote_tunnel.php in all versions up to, and including, 3.0.2. This makes it possible for unauthenticated attackers to read from or write to arbitrary files on the affected site's server which may make the exposure of sensitive information or remote code execution possible. |
| Certain models of routers from Billion Electric has hard-coded embedded linux credentials, allowing attackers to log in through the SSH service using these credentials and obtain root privilege of the system. |
| The WorkExaminer Professional server installation comes with an FTP server that is used to receive the client logs on TCP port 12304. An attacker with network access to this port can use weak hardcoded credentials to login to the FTP server and modify or read data, log files and gain remote code execution as NT Authority\SYSTEM on the server by exchanging accessible service binaries in the WorkExaminer installation directory (e.g. "C:\Program File (x86)\Work Examiner Professional Server"). |
| The administrative credentials can be extracted through application API responses, mobile application reverse engineering, and device firmware reverse engineering. The exposure may result in an attacker gaining full administrative access to the Gardyn IoT Hub exposing connected devices to malicious control. |
| Hardcoded credentials vulnerability in Trellix ePolicy Orchestrator (ePO) on Premise prior to 5.10 Service Pack 1 Update 2 allows an attacker with admin privileges on the ePO server to read the contents of the orion.keystore file, allowing them to access the ePO database encryption key. This was possible through using a hard coded password for the keystore. Access Control restrictions on the file mean this would not be exploitable unless the user is the system admin for the server that ePO is running on. |
| IBM Sterling Connect:Direct for UNIX Container 6.3.0.0 through 6.3.0.6 Interim Fix 016, and 6.4.0.0 through 6.4.0.3 Interim Fix 019 IBM® Sterling Connect:Direct for UNIX contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. |
| The `/etc/passwd` and `/etc/shadow` files reveal hard-coded password hashes for the operating system "root" user. The credentials are shipped with the update files. There is no option for deleting or changing their passwords for an enduser. An attacker can use the credentials to log into the device. Authentication can be performed via SSH backdoor or likely via physical access (UART shell). |
| Use of Hard-coded Credentials vulnerability in GoodWe Technologies Co., Ltd. GW1500‑XS allows anyone in physical proximity to the device to fully access the web interface of the inverter via Wi‑Fi.This issue affects GW1500‑XS: 1.1.2.1. |
| All the Toshiba printers contain a shell script using the same hardcoded key to encrypt logs. An attacker can decrypt the encrypted files using the hardcoded key. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system. |
| Use of Hard-coded Credentials vulnerability in weDevs WP Project Manager wedevs-project-manager allows Retrieve Embedded Sensitive Data.This issue affects WP Project Manager: from n/a through <= 2.6.25. |
| It was observed that all the Toshiba printers contain credentials used for WebDAV access in the readable file. Then, it is possible to get a full access with WebDAV to the printer. As for the affected products/models/versions, see the reference URL. |
| A flaw was found in Keycloak. This issue occurs because sensitive runtime values, such as passwords, may be captured during the Keycloak build process and embedded as default values in bytecode, leading to unintended information disclosure. In Keycloak 26, sensitive data specified directly in environment variables during the build process is also stored as a default values, making it accessible during runtime. Indirect usage of environment variables for SPI options and Quarkus properties is also vulnerable due to unconditional expansion by PropertyMapper logic, capturing sensitive data as default values in all Keycloak versions up to 26.0.2. |