Search Results (789 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-7738 1 Redhat 2 Ansible Automation Platform, Ansible Automation Platform Developer 2026-04-15 4.4 Medium
A flaw was found in Ansible Automation Platform (AAP) where the Gateway API returns the client secret for certain GitHub Enterprise authenticators in clear text. This vulnerability affects administrators or auditors accessing authenticator configurations. While access is limited to privileged users, the clear text exposure of sensitive credentials increases the risk of accidental leaks or misuse.
CVE-2024-29146 2026-04-15 5.9 Medium
User passwords are decrypted and stored on memory before any user logged in. Those decrypted passwords can be retrieved from the coredump file. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References].
CVE-2024-4840 1 Redhat 1 Openstack 2026-04-15 5.5 Medium
An flaw was found in the OpenStack Platform (RHOSP) director, a toolset for installing and managing a complete RHOSP environment. Plaintext passwords may be stored in log files, which can expose sensitive information to anyone with access to the logs.
CVE-2025-53758 2026-04-15 N/A
This vulnerability exists in Digisol DG-GR6821AC Router due to use of default admin credentials at its web management interface. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the hardcoded default credentials stored in the firmware of the targeted device. Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device.
CVE-2024-33471 2026-04-15 7.2 High
An issue in the Sensor Settings of AVTECH Room Alert 4E v4.4.0 allows attackers to gain access to SMTP credentials in plaintext via a crafted AJAX request. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2025-27532 2026-04-15 6.5 Medium
A vulnerability in the “Backup & Restore” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to access secret information via multiple crafted HTTP requests.
CVE-2024-47056 1 Mautic 1 Mautic 2026-04-15 5.1 Medium
SummaryThis advisory addresses a security vulnerability in Mautic where sensitive .env configuration files may be directly accessible via a web browser. This exposure could lead to the disclosure of sensitive information, including database credentials, API keys, and other critical system configurations. Sensitive Information Disclosure via .env File Exposure: The .env file, which typically contains environment variables and sensitive application configurations, is directly accessible via a web browser due to missing web server configurations that restrict access to such files. This allows an unauthenticated attacker to view the contents of this file by simply navigating to its URL. MitigationUpdate Mautic to the latest Mautic version. By default, Mautic does not use .env files for production data. For Apache users: Ensure your web server is configured to respect .htaccess files. For Nginx users: As Nginx does not inherently support .htaccess files, you must manually add a configuration block to your Nginx server configuration to deny access to .env files. Add the following to your Nginx configuration for the Mautic site: location ~ /\.env { deny all; } After modifying your Nginx configuration, remember to reload or restart your Nginx service for the changes to take effect.
CVE-2025-14377 1 Rockwellautomation 1 Verve Asset Manager 2026-04-15 N/A
A security issue was discovered within the legacy Ansible playbook component of Verve Asset Manager, caused by plaintext secrets incorrectly stored when a playbook is running. This component has been retired and has been optional since the 1.36 release in 2024.
CVE-2025-3442 2026-04-15 N/A
This vulnerability exists in TP-Link Tapo H200 V1 IoT Smart Hub due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the Wi-Fi credentials stored on the vulnerable device.
CVE-2025-23027 2026-04-15 N/A
next-forge is a Next.js project boilerplate for modern web application. The BASEHUB_TOKEN commited in apps/web/.env.example. Users should avoid use of this token and should remove any access it may have in their systems.
CVE-2024-31587 1 Secu 1 Secustation Firmware 2026-04-15 6.5 Medium
SecuSTATION Camera V2.5.5.3116-S50-SMA-B20160811A and lower allows an unauthenticated attacker to download device configuration files via a crafted request.
CVE-2025-3784 1 Mitsubishielectric 1 Gx Works2 2026-04-15 5.5 Medium
Cleartext Storage of Sensitive Information Vulnerability in GX Works2 all versions allows an attacker to disclose credential information stored in plaintext from project files. As a result, the attacker may be able to open project files protected by user authentication using disclosed credential information, and obtain or modify project information.
CVE-2025-40753 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2024-33470 2026-04-15 4.9 Medium
An issue in the SMTP Email Settings of AVTECH Room Alert 4E v4.4.0 allows attackers to gain access to credentials in plaintext via a passback attack. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2025-59105 1 Dormakaba 1 Access Manager 2026-04-15 N/A
With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of missing encryption. Thus, essential files, such as "/etc/passwd", as well as stored certificates, cryptographic keys, stored PINs and so on can be modified and read, in order to gain SSH root access on the Linux-based K7 model. On the Windows CE based K5 model, the password for the Access Manager can additionally be read in plain text from the stored SQLite database.
CVE-2023-28912 2026-04-15 5.7 Medium
The MIB3 unit stores the synchronized phone contact book in clear-text, allowing an attacker with either code execution privilege on the system or physical access to the system to obtain vehicle owner's contact data. The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources.
CVE-2025-57806 2026-04-15 N/A
Local Deep Research is an AI-powered research assistant for deep, iterative research. Versions 0.2.0 through 0.6.7 stored confidential information, including API keys, in a local SQLite database without encryption. This behavior was not clearly documented outside of the database architecture page. Users were not given the ability to configure the database location, allowing anyone with access to the container or host filesystem to retrieve sensitive data in plaintext by accessing the .db file. This is fixed in version 1.0.0.
CVE-2025-0418 1 Valmet 1 Dna 2026-04-15 N/A
Valmet DNA user passwords in plain text. This practice poses a security risk as attackers who gain access to local project data can read the passwords.
CVE-2024-53651 2026-04-15 4.6 Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device.
CVE-2025-0142 2026-04-15 4.3 Medium
Cleartext storage of sensitive information in the Zoom Jenkins Marketplace plugin before version 1.4 may allow an authenticated user to conduct a disclosure of information via network access.