Search Results (259 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-46599 1 K3s 1 K3s 2026-04-15 6.8 Medium
CNCF K3s 1.32 before 1.32.4-rc1+k3s1 has a Kubernetes kubelet configuration change with the unintended consequence that, in some situations, ReadOnlyPort is set to 10255. For example, the default behavior of a K3s online installation might allow unauthenticated access to this port, exposing credentials.
CVE-2025-62877 1 Suse 1 Harvester 2026-04-15 9.8 Critical
Projects using the SUSE Virtualization (Harvester) environment may expose the OS default ssh login password  if they are using the 1.5.x or 1.6.x interactive installer to either create a new cluster or add new hosts to an existing cluster. The environment is not affected if the PXE boot mechanism is utilized along with the Harvester configuration setup.
CVE-2024-25972 1 Atsumi 1 Oet-213h-bts1 2026-04-15 8.3 High
Initialization of a resource with an insecure default vulnerability in OET-213H-BTS1 sold in Japan by Atsumi Electric Co., Ltd. allows a network-adjacent unauthenticated attacker to configure and control the affected product.
CVE-2019-25219 1 Asio 1 Cplusplus Library 2026-04-15 7.5 High
Asio C++ Library before 1.13.0 lacks a fallback error code in the case of SSL_ERROR_SYSCALL with no associated error information from the SSL library being used.
CVE-2025-2441 2026-04-15 4.6 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of confidentiality when a malicious user, having physical access, sets the radio in factory default mode where the product does not correctly initialize all data.
CVE-2025-24288 1 Versa 1 Director 2026-04-15 9.8 Critical
The Versa Director software exposes a number of services by default and allow attackers an easy foothold due to default credentials and multiple accounts (most with sudo access) that utilize the same default credentials. By default, Versa director exposes ssh and postgres to the internet, alongside a host of other services. Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. Workarounds or Mitigation: Versa recommends the following security controls: 1) Change default passwords to complex passwords 2) Passwords must be complex with at least 8 characters that comprise of upper case, and lower case alphabets, as well as at at least one digit, and one special character 3) Passwords must be changed at least every 90 days 4) Password change history is checked to ensure that the at least the last 5 passwords must be used when changing password. 5) Review and audit logs for all authentication attempts to check for unauthorized/suspicious login attempts and enforce remediation steps.
CVE-2025-41672 1 Wago 1 Device Sphere 2026-04-15 10 Critical
A remote unauthenticated attacker may use default certificates to generate JWT Tokens and gain full access to the tool and all connected devices.
CVE-2025-41713 1 Wago 1 Cc100 2026-04-15 6.5 Medium
During a short time frame while the device is booting an unauthenticated remote attacker can send traffic to unauthorized networks due to the switch operating in an undefined state until a CPU-induced reset allows proper configuration.
CVE-2025-59044 1 Himmelblau-idm 1 Himmelblau 2026-04-15 4.4 Medium
Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. Himmelblau 0.9.x derives numeric GIDs for Entra ID groups from the group display name when himmelblau.conf `id_attr_map = name` (the default configuration). Because Microsoft Entra ID allows multiple groups with the same `displayName` (including end-user–created personal/O365 groups, depending on tenant policy), distinct directory groups can collapse to the same numeric GID on Linux. This issue only applies to Himmelblau versions 0.9.0 through 0.9.22. Any resource or service on a Himmelblau-joined host that enforces authorization by numeric GID (files/dirs, etc.) can be unintentionally accessible to a user who creates or joins a different Entra/O365 group that happens to share the same `displayName` as a privileged security group. Users should upgrade to 0.9.23, or 1.0.0 or later, to receive a patch. Group to GID mapping now uses Entra ID object IDs (GUIDs) and does not collide on same-name groups. As a workaround, use tenant policy hardening to restrict arbitrary group creation until all hosts are patched.
CVE-2025-59090 1 Dormakaba 1 Kaba Exos 9300 2026-04-15 N/A
On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards.
CVE-2025-7353 1 Rockwellautomation 1 Controllogix 2026-04-15 N/A
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.
CVE-2025-41245 1 Vmware 3 Aria Operations, Cloud Foundation, Tools 2026-04-15 4.9 Medium
VMware Aria Operations contains an information disclosure vulnerability. A malicious actor with non-administrative privileges in Aria Operations may exploit this vulnerability to disclose credentials of other users of Aria Operations.
CVE-2025-53602 2026-04-15 5.3 Medium
Zipkin through 3.5.1 has a /heapdump endpoint (associated with the use of Spring Boot Actuator), a similar issue to CVE-2025-48927.
CVE-2025-2442 2026-04-15 6.8 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious user, having physical access, sets the radio to the factory default mode.
CVE-2025-2129 2026-04-15 5.6 Medium
A vulnerability was found in Mage AI 0.9.75. It has been classified as problematic. This affects an unknown part. The manipulation leads to insecure default initialization of resource. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. After 7 months of repeated follow-ups by the researcher, Mage AI has decided to not accept this issue as a valid security vulnerability and has confirmed that they will not be addressing it.
CVE-2025-1960 2026-04-15 9.8 Critical
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.
CVE-2024-8313 2026-04-15 N/A
An Exposure of Sensitive System Information to an Unauthorized Control Sphere and Initialization of a Resource with an Insecure Default vulnerability in the SNMP component of B&R APROL <4.4-00P5 may allow an unauthenticated adjacent-based attacker to read and alter configuration using SNMP.
CVE-2024-41995 1 Ricoh Company Ltd 1 Javatm Platform 2026-04-15 7.5 High
Initialization of a resource with an insecure default vulnerability exists in JavaTM Platform Ver.12.89 and earlier. If this vulnerability is exploited, the product may be affected by some known TLS1.0 and TLS1.1 vulnerabilities. As for the specific products/models/versions of MFPs and printers that contain JavaTM Platform, see the information provided by the vendor.
CVE-2024-41975 2026-04-15 5.3 Medium
An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs.