| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Micca KE700 system contains flawed resynchronization logic and is vulnerable to replay attacks. This attack requires sending two previously captured codes in a specific sequence. As a result, the system can be forced to accept previously used (stale) rolling codes and execute a command. Successful exploitation allows an attacker to clone the alarm key. This grants the attacker unauthorized access to the vehicle to unlock or lock the doors. |
| A vulnerability has been found in DJI Mavic Mini, Air, Spark and Mini SE up to 01.00.0500. Affected by this vulnerability is an unknown functionality of the component Enhanced Wi-Fi Pairing. The manipulation leads to authentication bypass by capture-replay. The attack must be carried out from within the local network. A high degree of complexity is needed for the attack. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| OneUptime is a solution for monitoring and managing online services. In version 10.0.11 and prior, the WebAuthn authentication implementation does not store the challenge on the server side. Instead, the challenge is returned to the client and accepted back from the client request body during verification. This violates the WebAuthn specification (W3C Web Authentication Level 2, §13.4.3) and allows an attacker who has obtained a valid WebAuthn assertion (e.g., via XSS, MitM, or log exposure) to replay it indefinitely, completely bypassing the second-factor authentication. No known patches are available. |
| OpenClaw before 2026.3.23 contains a replay identity vulnerability in Plivo V2 signature verification that allows attackers to bypass replay protection by modifying query parameters. The verification path derives replay keys from the full URL including query strings instead of the canonicalized base URL, enabling attackers to mint new verified request keys through unsigned query-only changes to signed requests. |
| Authentication Bypass by Capture-replay, Use of Password Hash With Insufficient Computational Effort vulnerability in rustdesk-client RustDesk Client rustdesk-client on Windows, MacOS, Linux, iOS, Android (Client login, peer authentication modules) allows Reusing Session IDs (aka Session Replay). This vulnerability is associated with program files src/client.Rs and program routines hash_password(), login proof construction.
This issue affects RustDesk Client: through 1.4.5. |
| SMTP service in (1) Microsoft Windows 2000 and (2) Internet Mail Connector (IMC) in Exchange Server 5.5 does not properly handle responses to NTLM authentication, which allows remote attackers to perform mail relaying via an SMTP AUTH command using null session credentials. |
| OpenAirInterface v2.2.0 accepts Security Mode Complete without any integrity protection. Configuration has supported integrity NIA1 and NIA2. But if an UE sends initial registration request with only security capability IA0, OpenAirInterface accepts and proceeds. This downgrade security context can lead to the possibility of replay attack. |
| Authentication Bypass by Capture-replay vulnerability in Elfatek Elektronics ANKA JPD-00028 allows Session Hijacking.This issue affects ANKA JPD-00028: before V.01.01. |
| Use of fixed learning codes, one code to lock the car and the other code to unlock it, in the Key Fob Transmitter in Cyclone Matrix TRF Smart Keyless Entry System, which allows a replay attack.
Research was completed on the 2024 KIA Soluto. Attack confirmed on other KIA Models in Ecuador. |
| Use of fixed learning codes, one code to lock the car and the other code to unlock it, the Key Fob Transmitter in KIA-branded Aftermarket Generic Smart Keyless Entry System, primarily distributed in Ecuador, which allows a replay attack.
Manufacture is unknown at the time of release. CVE Record will be updated once this is clarified. |
| SMB forced authentication vulnerability in versions prior to 2025.35.000 of Sage 200 Spain. This vulnerability allows an authenticated attacker with administrator privileges to obtain NTLMv2-SSP Hash by changing any of the paths to a UNC path pointing to a server controlled by the attacker. |
| Weak Security in the PF-50 1.2 keyfob of PGST PG107 Alarm System 1.25.05.hf allows attackers to compromise access control via a code replay attack. |
| A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.2), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.2). Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This could allow an on-path attacker between the engineering software and the controller to execute any previously recorded commands at a later time (e.g. set the controller to STOP), regardless whether or not the controller had a password configured. |
| The login mechanism via device authentication of CGFIDO from Changing Information Technology has an Authentication Bypass vulnerability. If a user visits a forged website, the agent program deployed on their device will send an authentication signature to the website. An unauthenticated remote attacker who obtains this signature can use it to log into the system with any device. |
| Credential disclosure vulnerability via the /staff route in GreaterWMS <= 2.1.49 allows a remote unauthenticated attackers to bypass authentication and escalate privileges. |
| Mengshen Wireless Door Alarm M70 2024-05-24 allows Authentication Bypass via a Capture-Replay approach. |
| IoT Haat Smart Plug IH-IN-16A-S v5.16.1 is vulnerable to Authentication Bypass by Capture-replay. |
| Cognex In-Sight Explorer and In-Sight Camera Firmware expose
a proprietary protocol on TCP port 1069 to perform management operations
such as modifying system properties. The user management functionality
handles sensitive data such as registered usernames and passwords over
an unencrypted channel, allowing an adjacent attacker to intercept valid
credentials to gain access to the device. |
| The session hijacking attack targets the application layer's control mechanism, which manages authenticated sessions between a host PC and a PLC. During such sessions, a session key is utilized to maintain security. However, if an attacker captures this session key, they can inject traffic into an ongoing authenticated session. To successfully achieve this, the attacker also needs to spoof both the IP address and MAC address of the originating host which is typical of a session-based attack. |
| An issue in the verifyPassword function of hexo-theme-matery v2.0.0 allows attackers to bypass authentication and access password protected pages. |