Search Results (298 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-2617 1 Beetel 2 777vr1, 777vr1 Firmware 2026-04-18 6.3 Medium
A vulnerability was found in Beetel 777VR1 up to 01.00.09. This affects an unknown function of the component Telnet Service/SSH Service. The manipulation results in insecure default initialization of resource. The attack can only be performed from the local network. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-25499 1 Bpg 2 Terraform-provider-proxmox, Terraform Provider 2026-04-17 7.5 High
Terraform / OpenTofu Provider adds support for Proxmox Virtual Environment. Prior to version 0.93.1, in the SSH configuration documentation, the sudoer line suggested is insecure and can result in escaping the folder using ../, allowing any files on the system to be edited. This issue has been patched in version 0.93.1.
CVE-2026-25894 1 Frangoteam 1 Fuxa 2026-04-17 9.8 Critical
FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. An insecure default configuration in FUXA allows an unauthenticated, remote attacker to gain administrative access and execute arbitrary code on the server. This affects FUXA through version 1.2.9 when authentication is enabled, but the administrator JWT secret is not configured. This issue has been patched in FUXA version 1.2.10.
CVE-2026-23116 1 Linux 1 Linux Kernel 2026-04-17 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: pmdomain: imx8m-blk-ctrl: Remove separate rst and clk mask for 8mq vpu For i.MX8MQ platform, the ADB in the VPUMIX domain has no separate reset and clock enable bits, but is ungated and reset together with the VPUs. So we can't reset G1 or G2 separately, it may led to the system hang. Remove rst_mask and clk_mask of imx8mq_vpu_blk_ctl_domain_data. Let imx8mq_vpu_power_notifier() do really vpu reset.
CVE-2025-13357 1 Hashicorp 1 Terraform Provider 2026-04-17 7.4 High
Vault’s Terraform Provider incorrectly set the default deny_null_bind parameter for the LDAP auth method to false by default, potentially resulting in an insecure configuration. If the underlying LDAP server allowed anonymous or unauthenticated binds, this could result in authentication bypass. This vulnerability, CVE-2025-13357, is fixed in Vault Terraform Provider v5.5.0.
CVE-2026-28775 2 Datacast, International Datacasting Corporation (idc) 3 Sfx2100, Sfx2100 Firmware, Sfx2100 Series Superflex Satellitereceiver 2026-04-17 9.8 Critical
An unauthenticated Remote Code Execution (RCE) vulnerability exists in the SNMP service of International Datacasting Corporation (IDC) SFX Series SuperFlex SatelliteReceiver. The deployment insecurely provisions the `private` SNMP community string with read/write access by default. Because the SNMP agent runs as root, an unauthenticated remote attacker can utilize `NET-SNMP-EXTEND-MIB` directives, abusing the fact that the system runs a vulnerable version of net-snmp pre 5.8, to execute arbitrary operating system commands with root privileges.
CVE-2026-1675 1 Wordpress 1 Wordpress 2026-04-15 5.3 Medium
The Advanced Country Blocker plugin for WordPress is vulnerable to Authorization Bypass in all versions up to, and including, 2.3.1 due to the use of a predictable default value for the secret bypass key created during installation without requiring users to change it. This makes it possible for unauthenticated attackers to bypass the geolocation blocking mechanism by appending the key to any URL on sites where the administrator has not changed the default value.
CVE-2026-26122 1 Microsoft 2 Aci Confidential Containers, Microsoft Aci Confidential Containers 2026-04-15 6.5 Medium
Initialization of a resource with an insecure default in Azure Compute Gallery allows an authorized attacker to disclose information over a network.
CVE-2026-34780 2 Electron, Electronjs 2 Electron, Electron 2026-04-15 8.4 High
Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. From versions 39.0.0-alpha.1 to before 39.8.0, 40.0.0-alpha.1 to before 40.7.0, and 41.0.0-alpha.1 to before 41.0.0-beta.8, apps that pass VideoFrame objects (from the WebCodecs API) across the contextBridge are vulnerable to a context isolation bypass. An attacker who can execute JavaScript in the main world (for example, via XSS) can use a bridged VideoFrame to gain access to the isolated world, including any Node.js APIs exposed to the preload script. Apps are only affected if a preload script returns, resolves, or passes a VideoFrame object to the main world via contextBridge.exposeInMainWorld(). Apps that do not bridge VideoFrame objects are not affected. This issue has been patched in versions 39.8.0, 40.7.0, and 41.0.0-beta.8.
CVE-2018-25193 1 Cesanta 1 Mongoose Web Server 2026-04-15 7.5 High
Mongoose Web Server 6.9 contains a denial of service vulnerability that allows remote attackers to crash the service by establishing multiple socket connections. Attackers can repeatedly create connections to the default port and send malformed data to exhaust server resources and cause service unavailability.
CVE-2018-25169 2 Ampps, Softaculous 2 Ampps, Ampps 2026-04-15 7.5 High
AMPPS 2.7 contains a denial of service vulnerability that allows remote attackers to crash the service by sending malformed data to the default HTTP port. Attackers can establish multiple socket connections and transmit invalid payloads to exhaust server resources and cause service unavailability.
CVE-2025-7353 1 Rockwellautomation 1 Controllogix 2026-04-15 N/A
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.
CVE-2025-59097 1 Dormakaba 1 Access Manager 2026-04-15 N/A
The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps. This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication: - Re-configure Access Managers (e.g. remove alarming system requirements) - Freely re-configure the inputs and outputs - Open all connected doors permanently - Open all doors for a defined time interval - Change the admin password - and many more Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet.
CVE-2023-42667 1 Intel 1 Core Ultra Processor 2026-04-15 7.8 High
Improper isolation in the Intel(R) Core(TM) Ultra Processor stream cache mechanism may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-41713 1 Wago 1 Cc100 2026-04-15 6.5 Medium
During a short time frame while the device is booting an unauthenticated remote attacker can send traffic to unauthorized networks due to the switch operating in an undefined state until a CPU-induced reset allows proper configuration.
CVE-2025-61481 1 Mikrotik 2 Routeros, Switchos 2026-04-15 10 Critical
An issue in MikroTik RouterOS v.7.14.2 and SwOS v.2.18 exposes the WebFig management interface over cleartext HTTP by default, allowing an on-path attacker to execute injected JavaScript in the administrator’s browser and intercept credentials.
CVE-2023-49141 1 Intel 1 Processors Stream Cache Mechanism 2026-04-15 7.8 High
Improper isolation in some Intel(R) Processors stream cache mechanism may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2024-8313 2026-04-15 N/A
An Exposure of Sensitive System Information to an Unauthorized Control Sphere and Initialization of a Resource with an Insecure Default vulnerability in the SNMP component of B&R APROL <4.4-00P5 may allow an unauthenticated adjacent-based attacker to read and alter configuration using SNMP.
CVE-2025-2129 2026-04-15 5.6 Medium
A vulnerability was found in Mage AI 0.9.75. It has been classified as problematic. This affects an unknown part. The manipulation leads to insecure default initialization of resource. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. After 7 months of repeated follow-ups by the researcher, Mage AI has decided to not accept this issue as a valid security vulnerability and has confirmed that they will not be addressing it.
CVE-2025-24288 1 Versa 1 Director 2026-04-15 9.8 Critical
The Versa Director software exposes a number of services by default and allow attackers an easy foothold due to default credentials and multiple accounts (most with sudo access) that utilize the same default credentials. By default, Versa director exposes ssh and postgres to the internet, alongside a host of other services. Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. Workarounds or Mitigation: Versa recommends the following security controls: 1) Change default passwords to complex passwords 2) Passwords must be complex with at least 8 characters that comprise of upper case, and lower case alphabets, as well as at at least one digit, and one special character 3) Passwords must be changed at least every 90 days 4) Password change history is checked to ensure that the at least the last 5 passwords must be used when changing password. 5) Review and audit logs for all authentication attempts to check for unauthorized/suspicious login attempts and enforce remediation steps.